ACS DM1000 C10 ESS

Brand: ACS
Model: DM1000 C10 ESS

Chamber Specifications

ItemValue
Temperature Range (°C)-75 to 180
Useful Capacity (l)1000
Internal Dimensions1040 x 1020 x 1020 mm
External Dimensions1287 x 2512 x 2180 mm
Temperature Fluctuation Min. (K)0.1
Temperature Fluctuation Max. (K)0.5
Temperature Changing Rate Heating -70 / +180°C (K/min)10.0
Temperature Changing Rate Cooling +180 / -70°C (K/min)10.0
Humidity Range Min. (%) [τ=-3/+94°C]10.0
Humidity Range Max. (%) [τ=-3/+94°C]98.0
Temperature Range for Climatic Test Min. (°C)10.0
Temperature Range for Climatic Test Max. (°C)95.0
Humidity Fluctuation Min. (%)1.0
Humidity Fluctuation Max. (%)3.0
Maximum Thermal Load (W) T=+25°C8000.0
Rated Power (kW)45.3
Rated Current Absorption (A)85.0
Weight (kg)1800.0
Sound Pressure Level dB(A)76.0
Supply Voltage (Vac)400V ±10%/50Hz/3 + N + G

More ACS Environmental Stress Screening Chambers

ACS DM340 C ES

ACS DM600 C ES

ACS DM1200 C ES